November 4, 2026 · 6 min read

Partial Power Outage: Why Half Your House Has No Power

A partial power outage, where some of the house works and some doesn't, has two main causes. The common, minor one is a tripped breaker or GFCI device that has shut off one circuit. The serious one is a lost leg of your electrical service, where one of the two hot conductors feeding the house has failed at the panel, the meter, or the utility connection. If 240-volt appliances have stopped working or lights are unusually dim or bright, turn off large appliances and call your utility or an electrician.

Candle lantern glowing on a windowsill in an otherwise dark roomSafety

What is a partial power outage?

It is any outage that affects part of a home rather than all of it. To understand why that happens, it helps to know how a house is fed. A standard residential service delivers two 120-volt hot legs and a neutral. Half the breakers in your panel draw from one leg and half from the other; 240-volt appliances such as the range, dryer, water heater, and heat pump use both legs at once.

So when one room goes dark, a single circuit has tripped. When roughly half the house goes dark in no logical pattern, and the 240-volt appliances quit, one whole leg is missing.

How do I tell which kind I have?

A few quick observations will sort it, without opening anything.

  • One room or one group of outlets is dead: a tripped breaker or GFCI
  • Outlets in a bathroom, kitchen, garage, or outdoors are dead: a tripped GFCI, possibly located in a different room
  • About half the house is dead, scattered across rooms: a lost service leg
  • Range, dryer, or water heater won't run or runs weakly: a lost service leg
  • Lights are dim, or some are brighter than normal: a service or neutral problem — urgent
  • Neighbors are having the same trouble: a utility problem

What should I check first?

Go to the panel and look for a breaker that is not lined up with the others. A tripped breaker often sits in a middle position rather than fully off. To reset it, push it firmly to off first, then back to on. If it holds, note what was running when it tripped. If it trips again immediately, leave it off; there is a fault on that circuit.

Next, look for tripped GFCI devices. These are the outlets with test and reset buttons, and one GFCI commonly protects other ordinary-looking outlets downstream, sometimes in another room or outside. Check bathrooms, the kitchen, the garage, the basement, and exterior outlets, and press reset on any that have popped.

If every breaker is on and every GFCI is reset and part of the house is still dead, stop there. The problem is not something to solve from the front of the panel.

What causes a lost leg of power?

One of the two hot conductors has stopped delivering voltage somewhere between the utility transformer and your panel's bus. The break can be on either side of the meter.

  • Utility side: a failed connection at the transformer or pole, a damaged service drop, or a failing underground service lateral
  • At the meter base: a burned or loose jaw or lug
  • At the panel: a failed main breaker, a loose main lug, or a burned bus stab
  • Storm damage: a tree limb pulling on the overhead service, or water entering the meter base or panel

Why is a lost leg dangerous?

Two reasons. First, the place where the connection failed is usually still partly connected, and a poor connection under load generates heat. That is how meter bases and panels burn.

Second, 240-volt appliances bridge the two legs. With one leg dead, voltage can feed backward through a water heater or dryer element onto the dead side, so circuits there may show a weak, unstable voltage. Motors and electronics run on that can be damaged. If the neutral is the conductor that has failed rather than a hot leg, the effect is worse: some circuits see low voltage and others see high voltage, which can destroy equipment within minutes.

What should I do if I suspect a lost leg?

Reduce the load and get help. Do the following, in this order.

  • Turn off the breakers for 240-volt appliances: range, dryer, water heater, heat pump or AC, EV charger
  • Unplug sensitive electronics
  • Do not remove the panel cover or touch the meter
  • Stay clear of any downed or sagging overhead line and report it to the utility
  • Ask a neighbor whether they are affected
  • Call your utility to report a partial outage; they will check their side of the meter
  • If the utility finds its side is sound, call an electrician for the meter base and panel
  • If you smell burning or see scorching at the panel or meter, turn off the main if it is safe to reach and call for emergency service

Who fixes it: the utility or an electrician?

It depends on where the failure is. The utility is responsible for its transformer, its lines, and typically the service drop up to the point of connection at your house. The homeowner is generally responsible for the meter base, the service mast or riser, the conductors into the panel, and the panel itself, though the exact dividing line varies by utility and by whether the service is overhead or underground.

In practice the utility usually comes first, because it can confirm whether full voltage is arriving at the meter. If it is, the fault is in your equipment and that is our work: replacing a damaged meter base, main breaker, or panel, under a permit, with the utility disconnecting and reconnecting the service.

Can a partial outage be prevented?

Service connections fail gradually. The earlier signs are lights that flicker throughout the house, lights that dim hard when large appliances start, a buzzing panel, or a warm main breaker. A periodic look inside the panel by an electrician, checking terminations for looseness and heat discoloration, catches most of these before they turn into an outage on a cold night.

Common questions

Why does half my house have no power?
Either a breaker or GFCI has tripped and shut off a circuit, or your home has lost one of the two hot legs of its electrical service. If the breakers are all on and 240-volt appliances have stopped working, it is likely a lost leg, and you should call your utility or an electrician.
Is a partial power outage dangerous?
It can be. A lost service leg or a failing neutral means a connection is overheating somewhere, and abnormal voltage can damage appliances. Turn off large appliances and have it checked promptly.
Should I call the power company or an electrician for a partial outage?
Start with the utility if the breakers are all on; they can verify whether full voltage is reaching your meter. If the utility's side is fine, the fault is in your meter base or panel and an electrician makes the repair.
No breakers are tripped but some outlets don't work. Why?
Check for a tripped GFCI outlet, which can cut power to other outlets downstream. If none are tripped, a connection may have failed on that circuit, or the home may have lost a service leg.
Written by the licensed electricians at Paramount Electric Co. (OR CCB #195783 · ELEC C818) and reviewed by Maurice Greven, Project Manager / Supervisor, who holds Oregon supervising electrician license #4828S. Have a job this applies to? Call (971) 471-7897 or request service online.

Part of the house dark with every breaker on?

Call our 24/7 on-call line. We'll help you work out whether it's the utility's side or yours, and repair it if it's yours.