Milwaukie, OR · 2026 · In progress

Linden Care Home RCF

Ground-up electrical construction, now underway, for the new 21-unit Linden Care Home — an 800A single-phase service, full building electrical, a Type I hood commercial kitchen, and a 48kW standby generator carrying life-safety and resident-care loads.

Rendering of the Linden Care Home entrance with covered pergola walkwayCommercial
1 / 3
800A 1Ø
Service
48kW generator
Standby power
21
Units

The Challenge

A residential care facility layers life-safety requirements on top of a full commercial buildout: emergency egress lighting, a fire alarm system coordinated with sprinklers, and backup power planned for medication refrigeration, kitchen equipment, HVAC, water heating, and selected resident-room receptacles for potential medical equipment.

Our Approach

The electrical design centers on an 800A single-phase service with a 48kW standby generator serving designated life-safety and operational loads — egress and corridor lighting, selected exterior lighting, furnaces, water heating, designated kitchen equipment, medication refrigeration, common-area equipment, and selected resident-room receptacles — alongside the full building electrical and a Type I hood kitchen requiring fire-suppression and makeup-air coordination.

Current Status

Progress, October 2026: the 800A service is complete — meter, wireway, generator transfer switch, disconnects, and distribution set on the exterior wall — and interior rough-in is now underway. This entry keeps growing with progress photos through kitchen rough-in and finish.

Questions from the job

What size is the service, and what's on the generator?
800 amps, 120/240, single-phase. 48 kW standby on a named list: egress and corridor lights, some exterior, furnaces, water heat, the kitchen equipment that was called out, med refrigeration, some resident receptacles. Not every breaker in the building.
Is it finished?
No. Service wall was in (meter, wireway, switch, disconnects, distribution) and rough-in had started. The kitchen is a Type I hood. Suppression and makeup air still have to interlock.
Why does a 21-unit care home have a commercial kitchen scope?
Because that kitchen is commercial. Hood, suppression, makeup air. Circuits off the appliance list. A residential range circuit will not stretch.
Who owns the fire alarm?
It's in our scope with the egress lights and the generator. The jurisdiction classifies the loads. We build what they signed.