Backup Power for Healthcare & Senior Care Facilities in Oregon

For most businesses an outage is lost revenue. For a clinic it's a refrigerator full of vaccines; for a care home it's residents on oxygen concentrators, a dark stairwell, and a building that's getting cold. Oregon's ice storms and windstorms have made multi-day outages a planning assumption rather than a rare event. This guide covers what healthcare and senior care operators should understand about backup power — what's required, what's wise, and how a project comes together.

Empty institutional corridor with wall handrails, fluorescent ceiling lights, and an illuminated exit sign at the far endCommercial

What backup power does a healthcare or senior care facility need?

At minimum, a facility needs standby power for life-safety systems and for the loads that protect patients and residents: egress lighting, fire alarm, medical and medication refrigeration, essential medical equipment, heating, nurse-call and communications. What is legally required depends on the facility's license type and occupancy, so confirm the specifics with your licensing agency and the local building official.

Beyond the required loads is the operational question: what does the building need to keep caring for people through an outage that lasts days? For many senior care operators the practical answer is most of the building, because relocating residents is far harder than powering them.

  • Egress and emergency lighting, exit signs
  • Fire alarm and life-safety systems
  • Vaccine, medication, and food refrigeration
  • Medical equipment and selected patient-care receptacles
  • Heating, ventilation, and where needed, cooling
  • Nurse-call, phones, network, and security
  • Elevators, where residents can't use stairs
  • Kitchen equipment needed to keep serving meals

What is the difference between emergency, legally required, and optional standby power?

The National Electrical Code separates backup power into three categories. Emergency systems (Article 700) serve loads essential to life safety and must pick up within seconds. Legally required standby (Article 701) serves loads that a code or agency mandates but that aren't direct life safety. Optional standby (Article 702) covers everything an owner chooses to back up for business reasons.

The distinction matters because the categories are wired differently. Emergency circuits have to be kept separate from other wiring and are served by their own transfer equipment, and healthcare occupancies add further rules for how essential loads are divided into branches. A generator that feeds everything through one transfer switch is fine for a business that simply wants to stay open; it isn't a compliant design for a facility with required emergency loads.

Getting the classification right at the start drives the number of transfer switches, the panel layout, and the cost. It's a question for the design team and the authority having jurisdiction, answered before equipment is ordered.

How is the generator sized?

From a load study, not from square footage. We total the loads the generator has to carry, account for the starting current of motors like HVAC compressors and elevators, and decide which loads can be staged or shed. The result is a generator matched to real demand, with a defined margin for growth.

Load management is what keeps the size reasonable. Staging HVAC startup and automatically shedding nonessential loads lets a smaller generator hold the critical ones without stalling. On a pediatrics clinic we completed in Clackamas, a 150 kW natural-gas generator feeds a dedicated standby panel through a 600-amp automatic transfer switch, with load management that keeps refrigeration, selected exam-room receptacles, essential lighting, IT, and security at the front of the line.

Natural gas or diesel?

Both are used. Natural gas offers continuous fuel supply with no on-site storage or refueling, runs cleaner, and suits most clinics and many care facilities. Diesel stores its fuel on site, which makes it independent of the gas utility, and is common on larger systems and where on-site fuel storage is required for the emergency system.

Whether on-site fuel is required for a particular facility is a code and licensing determination. Where it isn't, the choice comes down to gas service capacity at the site, the size of the generator, run-time expectations, and the owner's appetite for fuel maintenance. We coordinate the gas-service or tank scope either way.

What testing and maintenance is expected?

Facilities with required emergency power systems are generally expected to exercise the generator on a regular schedule, test it under load, test the transfer switches, and keep written records — the recognized standard is NFPA 110. Surveyors and inspectors ask to see those logs. Your licensing agency and local authority set what applies to your facility.

Even where no rule requires it, the logic holds: a generator that hasn't run under load is a guess. Annual service — oil and filter, battery load test, controller check, a test run under load — plus routine exercise is what turns the equipment into something staff can rely on. Remote monitoring adds an alert when a unit faults or misses its exercise cycle.

We maintain standby systems we installed and systems we didn't, and train facility staff on operation and what the monthly exercise should look like.

How long does a project take, and what's involved?

A standby power project runs through a load study and design, permitting, equipment procurement, site work, installation, startup, and testing. Equipment lead time is typically the longest step for commercial generators and transfer switches, so the sooner the unit is sized and released, the sooner the building is protected.

The work at an operating facility is planned around care. The cutover to the new transfer equipment requires a brief, scheduled outage, coordinated with administration in advance, with temporary provisions for anything that can't be without power. Generator placement accounts for clearances, exhaust, and sound — a sound-attenuated enclosure matters when the unit sits outside resident rooms.

  • Load study and classification of required versus optional loads
  • Generator, transfer switch, and distribution design
  • Electrical permit and plan review; gas or fuel coordination
  • Concrete pad, underground raceways, and feeders
  • Installation, grounding, and controls
  • Manufacturer startup, load-bank testing, and inspection
  • Staff training and maintenance handoff

What if a facility already has a generator?

Then the question is whether it still covers what the building has become. Facilities add equipment, wings, and HVAC over the years while the generator stays the same size. A review compares the present-day loads to the generator and transfer equipment, confirms the system is wired the way current code and licensing expect, and checks the maintenance record.

Common findings are a generator that's now undersized for the connected load, critical equipment that was never moved onto the standby panel, and transfer switches that haven't been tested in years. All are fixable, and far better found in a review than in January.

Common questions

Does every medical office need a generator?
No. Requirements depend on the type of care provided and the building's occupancy classification. Many outpatient clinics install standby power by choice — to protect refrigerated medications and stay open — rather than because a code requires it. Your licensing agency and local building official can confirm what applies.
Are you a Generac dealer?
Yes. Paramount Electric Co. is a Generac Authorized Dealer. We size, install, commission, and maintain standby generators and transfer switches, and we install owner-furnished equipment as well.
Can you install a generator without shutting down the facility?
Most of the work happens with the building running. The final connection to the transfer equipment needs a short, planned outage, which we schedule with your staff and support with temporary measures for critical loads.
Do you include backup power in a new construction or renovation bid?
Yes. For general contractors and developers building healthcare and senior care projects, we carry the generator, transfer switches, and emergency distribution in the same electrical bid.